Overview
An economical alternative to integrated heating baths for liquid temperature up to 150°C. Controller bridge rests securely on the deep drawn stainless steel reservoir, yet is easily removed for tank cleaning. Generous bath opening provides ready access to samples and the included bath cover improves stability.
Features
- Working temperatures from ambient 10° up to 150°C (MX Controller up to 135°C)
- Advanced Programmable, Advanced Digital or MX Temperature Controller
- 6, 10, 20 or 28 liter reservoir
- DuraTop™ Chemical Resistant Bridge, Swivel 180™ Rotating Controller (on Advanced Programmable and Advanced Digital models)
- Lidded opening for optional cooling coil
- External circulation capability
- Complies with DIN 12876-1 Class I safety requirements for use with non-flammable liquids
- Includes bath cover
Key Attributes
Type | Stirred / Circulating Baths |
Incubation | Yes |
Refrigeration | Accessory |
Temp Range (°C) | Ambient 10 to 150 |
Capacity (L) | 10 |
Circulation | Internal & External |
Brand | PolyScience |
MaxFlow Rate (l/min) | 20.1, 13.5 |
Temp Stability (°C) | ±0.01, ±0.07 |
Timer | Yes |
Alarms | Yes |
Digital or Mechanical | Digital |
Data connection | Yes |
Tank Material | Stainless Steel |
Sample Agitation | No |
Media Racks Available | Yes |
Warranty (years) | 2 |
Weight (lb) | |
Width (in) | 13.9 |
Depth (in) | 13.5 |
Height (in) | 14.9 |
Manufacturer specifications
Controller |
Advanced Programmable |
Advanced Digital |
Economy MX |
Part Number |
AP10S150-A11B |
AD10S150-A11B |
MX10S135-A11B |
Working Temperature Range °C |
Ambient 10° to 150° |
Ambient 10° to 150° |
Ambient 10° to 135° |
Reservoir Capacity (liters) |
10 |
10 |
10 |
Reservoir/Tank Material |
Stainless Steel |
Stainless Steel |
Stainless Steel |
Reservoir Cover |
Included |
Included |
Included |
DuraTop |
Yes |
Yes |
Yes |
Working Access (L x W x D) (inches) |
3.9 x 10.1 x 6 in |
3.9 x 10.1 x 6 in |
3.9 x 10.1 x 6 in |
Temperature Stability °C |
±0.01° |
±0.01° |
±0.07° |
Display |
4.3" SmartTouch Touchscreen |
3.75" Touch-Pad LCD |
3.25" LCD |
Display Resolution (Set) |
0.01 |
0.01 |
0.1 |
Display Resolution (Read) |
0.001 |
0.01 |
0.1 |
Pump Type |
Pressure/Suction |
Pressure/Suction |
Pressure |
Pump Speed |
Variable |
Variable |
One |
Process Connections |
1/4" (F) NPT |
1/4" (F) NPT |
1/2" O.D. Barbed Tubes |
External Temperature Control Capability |
Yes |
Yes |
N/A |
Flammability Class (DIN 12876-1) |
I (NFL) |
I (NFL) |
I (NFL) |
Over-Temperature Protection / Failsafe Heater Control |
Yes |
Yes |
Yes |
Low Liquid Level Protection |
Yes |
Yes |
Yes |
Cooling Coil |
Accessory |
Accessory |
Accessory |
Included Software |
PolyTemp, TDMS file, USB driver, Time/Temp Program Generator, PolyTemp Remote iPhone app |
PolyTemp Viewer, USB driver |
N/A |
Maximum Ambient Temperature °C |
35° |
35° |
35° |
Overall Dimensions (L x W x H) (inches) |
13.9 x 13.5 x 14.9 in |
13.9 x 13.5 x 14.9 in |
13.9 x 13.5 x 16 in |
Environmental Compliance |
RoHS, WEEE |
RoHS, WEEE |
RoHS, WEEE |
Shipping Weight (pounds) |
45 |
45 |
39 |
Maximum Pressure (psi) |
4.3 |
4.3 |
2.3 |
Maximum Pressure Flow Rate (l/min) |
20.1 |
20.1 |
13.5 |
Maximum Suction Flow Rate (l/min) |
14.7 |
14.7 |
N/A |
Included Hardware |
Nylon hose adapters for 3/8", 1/4", and 3/16" |
Nylon hose adapters for 3/8", 1/4", and 3/16" |
Fitting Kit for External Applications |
Heater Wattage |
1100 |
1100 |
1100 |
Electrical Requirements (VAC/Hz/Ph/A) |
120/60/1/10 |
120/60/1/10 |
120/60/1/10 |
Regulatory Approvals |
ETL |
ETL |
ETL |
Controllers
Specifications and features for the PolyScience Stainless Steel Open Bath Systems vary based on the controller chosen. Some key specifications are in the table below, and additional features for each controller are listed below the table.
Advanced Programmable | Advanced Digital | Economy MX | |
Temp. Range (°C) | Ambient 10°C to 150°C | Ambient 10°C to 150°C | Ambient 10°C to 135C |
Temp. Stability | ±0.01°C | ±0.01°C | ±0.07°C |
External Temp. Control | Yes (probe not included) | Yes (probe not included) | No |
Pump | Pressure/Suction, Variable-Speed | Pressure/Suction, Variable-Speed | Pressure only, 1-speed |
Programmability | Ten 100-step programs | N/A | N/A |
External Circulation | Open or closed loop | Open or closed loop | Closed loop |
Safety Rating* | DIN 12876-1 Class III | DIN 12876-1 Class III | DIN 12876-1 Class I |
*DIN 12876-1 Class III devices are rated for use with flammable liquids. DIN 12876-1 Class I devices may be used with non-flammable liquids only.
Advanced Programmable Features
- Time/temperature programming (ten 100-step programs)
- Intuitive 4.3” (10.9 cm) SmartTouch™ display
- 6 languages: French, German, Spanish, Chinese, Arabic, English
- Variable speed pump with open- and closed-loop external circulation capability
- Swivel 180™ Rotating Controller
- On-board connectivity: USB-A & B, Ethernet, RS232/485, and external temperature probe
- Event scheduling (time & date) with real-time clock
- Review temperature trends for up to 10 days
- Multiple selectable “home” screens
- On-screen help
- Automatic and/or user-adjustable performance optimization
- 5-point calibration capability
Advanced Digital Features
- Intuitive 3.75” (9.5 cm) display with touch-pad control
- 4 languages: French, German, Spanish, English
- Swivel 180™ Rotating Controller
- On-board connectivity: USB-A & B, Ethernet, RS232/485, and external temperature probe
- On-screen prompts
- Automatic performance optimization and specific heat tuning
- Single-point calibration capability
Economy MX Features
- Large, universal icon and English display
- On-screen prompts
- Single-point calibration capability
FAQ
I would like to perform a heating / cooling program where the temperature ramps from one set point to another over time. Are the PolyScience 10 Liter Stainless Steel Open Bath Systems capable of this?
That depends on the controller used. Only the Advanced Programmable controller can be programmed to perform ramps.
It is possible to have the circulation on without any temperature control being on?
No. If the circulation is on, then a temperature setting must be selected.